Toggle Navigation Toggle Navigation
  • Lumen Connect overview
  • Getting started/General
  • Services
  • APIs
  • Monitoring & Reports
  • Billing
  • Admin
  • Support
  • Orders (Wholesale)
  • Other portals overview
  • Media portal
  • DDoS Mitigation & Reporting
  • Security Solutions portal
  • VoIP portal
  • View all product support
  • Infrastructure
  • Connectivity
  • Security
  • Communication
  • Media & Entertainment
  • LSR portal
  • Port Out Request tool
  • Virtual Front Office
  • Readiness overview
  • Product-specific readiness
  • Handbooks
  • All infrastructure services
  • Edge Bare Metal
  • Edge Gateway
  • Edge Private Cloud
  • Encrypted Wavelength Service
  • Network Storage
  • All connectivity services
  • Ethernet On-Demand
  • Fiber+ Internet
  • Internet On-Demand
  • IP VPN On-Demand
  • NaaS Port
  • On-Demand services
  • Troubleshooting tools
  • All security services
  • Adaptive Network Security
  • Adaptive Threat Intelligence
  • Application Delivery Solutions
  • DDoS Hyper
  • DDoS Mitigation Service
  • Lumen Defender Powered by Black Lotus Labs
  • Lumen SASE with Fortinet
  • Lumen SASE with Versa
  • Lumen SASE with VMware
  • Network-based Security
  • SD-WAN with Cisco Meraki
  • SD-WAN with Versa Networks
  • Security Log Monitoring
  • All communication services
  • Cloud Voice
  • Hosted VoIP
  • Local Inbound (LI)
  • Lumen Solutions for Microsoft Teams
  • Lumen Solutions for Webex
  • Lumen Solutions for Zoom
  • Lumen Solutions for Zoom for Government
  • SIP Trunking
  • Unified Communications and Collaboration
  • Voice Complete
  • VoIP Enhanced Local (ELS)
  • VoIP services
  • Vyvx® Broadcast Solutions
  • North America
  • Asia Pacific (APAC)

Adding dedicated 8XX using DTFO

To add a dedicated 8XX using DTFO:

  1. Using the left menu, click Orders, click Manage Orders, then click Add.
  1. From the Service Type list, select 8XX.
  1. Select the Dedicated radio button (in the 8XX Type field).
  1. From the Order Type list, select the type of order you're submitting:

    • New—8XX reserved to CenturyLink Resp Org LGT01.

    • Porting—porting from other Resp Org to CenturyLink Resp Org.

    • Complementary—your company has Resp Org control of the 8XX.
  1. From the Customer Account Number list, select the desired account.
  1. From the Product Account ID/Product Description list, select the desired product account.
  1. Click Go.

    Lumen Connect builds the order form.

Adding features

  1. Select Current RespOrg ID:

    • For Order Type of New, the Current RespOrg ID field defaults to LGT01.

    • For Order Type of Porting, select the current Resp Org ID (that the 8XX is porting from) in the Current RespOrg ID list.

    • For Order Type of Complementary select the Complementary Carrier Resp Org ID in the Current RespOrg ID list.
  1. From the Originating Routing list, select the area and class of service (i.e. toll-free coverage: 48 states, 50 states, Canada, etc.).
  1. Primary Trunk provides a list of trunk groups on the Enterprise; you can also type alpha/numeric characters in the field to filter the list and find a specific trunk group type, trunk group number, trunk group name, switch ID or city.
  1. If you want to add DTO (dedicated termination overflow), under DTO Number(s), select the checkbox next to First DTO, Second DTO and/or ANI (as needed).
  1. Select Yes or No for Real Time ANI Requested.

    • Real Time ANI allows dedicated access for you to receive the ANI of the calling party if the call originates from an equal access end office.

    • Real Time ANI is currently provided via in‑band signaling. Terminating equipment must accept Feature Group D (FGD) signaling.

    • Real Time ANI must be added on the trunk group prior to adding the feature to a Toll Free number.

Adding 8XX numbers

  1. Select from DNIS Length list if desired. (If DNIS Length is selected and DNIS value is not entered, Lumen Connect assigns a DNIS value.)
  1. Use the 8XX List field to add up to 1,000 toll‑ree numbers. You can paste your list from Word, Excel, Notepad, or WordPad, or other word processing, spreadsheet, or text editor. Do the following to ensure that your text is formatted correctly:

    • Each toll‑free number must be ten digits long and cannot include parentheses, spaces, or hyphens.
    • Each DNIS number must equal the value entered in the DNIS Length field. (If the DNIS number value is blank, the system will generate the DNIS value beginning with the last digit of the toll‑free number.)
    • DNIS length must between 2‑10 digits in length.
    • Each toll‑free row must include a space between the toll‑free number and DNIS.
    • Each toll‑free row must terminate with a carriage return.

Validating 8XX numbers

  1. Click Validate.

    Lumen Connect checks the data you entered in the 8XX List field. Correct any errors, then click Validate again. Repeat this process until Lumen Connect shows a Validation Complete, No Errors message.

Adding contacts

Order information and attachments

  1. In the Company/End User Name field, type the name of your customer.
  1. In the Customer Request Date field, use the calendar icon to select a service installation date. (This must be next day or future date.)
  1. If needed, use the Customer PON and Related Customer PON fields to add related order information to help in your tracking.
  1. If you're porting numbers, use the calendar icon in the LOA Date field to select the date of the LOA you're attaching in the next section.
  1. Enter any additional information not already captured in the order fields in the Comments field.
  1. Use the attachments section to add attachments (up to 10) related to the order, such as an LOA, End User Link Letter, (LOA), or bill copy. When changing an existing STG/ISO by adding or removing member trunk groups, you must attach the Wholesale Toll Free Super Trunk & In Switch Overflow order form for additional provisioning.

Saving or submitting your order